Application
- Drop Cables
- Broadband network - Local loop
- FTTX networks
- Aerial or Duct
Features
- Universal design
- Maximum bandwidth
- Excellent crush resistance
- Reduces cable preparation and installation time - Easy location after installation
Mechanical Specifications | |
Max. Tensile Strength | 1350 N (303 lb) |
Min. Bend Radius Installation | 20 times x cable O.D. |
Min. Bend Radius Operation | 10 times x cable O.D. |
Nominal Outer Diameter | 4.5 mm x 10.2 mm (0.18 in x 0.40 in) |
Cable Design | |
Fibers per Tube | Up to 2 |
Fiber Count | Up to 4 |
Inner Jacket Color | Natural |
Outer Jacket Color | Black |
Outer Jacket Material | Polyethylene (PE) |
Toning Conductor | Copper Wire, 24 AWG |
General Specifications | |
Application | Drop cables |
Tube Type | Dry |
Fiber Type | Single-Mode (OS2) |
Fiber & Tight Buffer Coloring( l : Black Dot Marking) |
Ordering Information | |
Weight | 40 kg/km (27 lb / 1,000 ft) |
Length / Reel | 4 km (13,000 ft) without pallet |
Standards | |
RoHS | Free of hazardous substances according to RoHS 2011/65/EU |
Standards | IEC 60794: Basic requirements for optical fiber and cable elements ANSI/ICEA S-87-640: Standard for optical fiber outside plant communications cable |
Environmental Conditions | |
Temperature Range, Installation | - 10°C to +40°C (14°F to 104°F) |
Temperature Range, Storage | - 30°C to +60°C (-22°F to 140°F) |
Temperature Range, Operation | - 30°C to +60°C (-22°F to 140°F) |
Optical Characteristics (Single-mode) | |
Fiber Category | G.652.D / G.657.A1 |
Attenuation after cable | 0.35 dB/km / 0.35 dB/km / 0.25 dB/km |
Wavelengths | 1310 nm / 1383 nm / 1550 nm |