Applications
- FTTx networks
- Indoor / Outdoor
- Suitable for underground duct installations
Features
- Single jacket with ripcords for easy stripping
- Contains non-metallic strength member
- PE Jacket
Mechanical Specifications | |||||||||
Fiber Count | 12 - 48 | 72 | 96 | 144 | 288 | 432 | 432 | 567 | 864 |
Fibers per Tube | 12 | 24 | |||||||
Nominal Outer Diameter | 9.1 mm (0.36 in) | 9.7 mm (0.38 in) | 11.0 mm (0.43 in) | 13.6 mm (0.54 in) | 15.9 mm (0.63 in) | 18.1 mm (0.71 in) | 16.9 mm (0.67 in) | 19.8 mm (0.78 in) | 22.3 mm (0.88 in) |
Max. Tensile Strength, Long-Term | 450 N (101 lb) | 640 N (144 lb) | |||||||
Max. Tensile Strength, Short-Term | 1200 N (270 lb) | 2200 N (495 lb) | |||||||
Min. Bend Radius Installation | 20 times x cable O.D. | ||||||||
Min. Bend Radius Operation | 10 times x cable O.D. |
Cable Design | ||||||||
Fiber Count | 12 - 48 | 72 | 96 | 144 | 288 | 432 | 567 | 864 |
Fiber Color | Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Pink, Aqua | |||||||
Tube Color Coding | Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Pink, Aqua | |||||||
Outer Jacket Color | Black | |||||||
Outer Jacket Material | Polyethylene(PE) |
Fiber Coloring( l : Black Stripe Marking) |
General Specification | |
Environment | Indoor / Outdoor |
Cable Type | Gel-filled Tube |
Fiber Type | Single-Mode(OS2) |
Application | Duct |
Standards | |
RoHS | Free of hazardous substances according to RoHS 2011/65/EU |
Standards | IEC60794 : Basic requirements for optical fiber and cable elements ANSI/ICEA S-87-640 : Standard for optical fiber outside plant communications cable |
Design and Test Criteria | ANSI/ICEA S-87-640 |
Ordering Information | |||||||||
Fiber Count | 12 - 48 | 72 | 96 | 144 | 288 | 432 (12F) | 432 (24F) | 567 | 864 |
Weight | 61 kg/km (41 lb/1,000ft) | 73 kg/km (49 lb/1,000ft) | 93 kg/km (62 lb/1,000ft) | 146 kg/km (98 lb/1,000ft) | 197 kg/km (132 lb/1,000ft) | 249 kg/km (167 lb/1,000ft) | 215 kg/km (144 lb/1,000ft) | 290 kg/km (195 lb/1,000ft) | 374 kg/km (251 lb/1,000ft) |
Container Loading Capacity (40ft Container) | 98 km (320,000 ft) | 98 km (320,000 ft) | 85 km (280,000 ft) | 79 km (260,000 ft) | 67 km (220,000 ft) | 55 km (180,000 ft) | 67 km (220,000 ft) | 55 km (180,000 ft) | Requires discussion |
Length / Reel | 6.096 km (20,000 ft) |
Environmental Conditions | |
Temperature Range, Installation | - 30 °C to +70 °C (-22 F to 158 F) |
Temperature Range, Storage | - 40 °C to +70 °C (-40 F to 158 F) |
Temperature Range, Operation | - 40 °C to +70 °C (-40 F to 158 F) |
Optical Characteristics (Single-mode) | |
Fiber Category | G.652.D |
Attenuation after cable | 0.36 dB/km / 0.36 dB/km / 0.25 dB/km |
Wavelengths | 1310 nm / 1383 nm / 1550 nm |
Datasheet download | Duct (Gel) Cable Datasheet |