HYESUNG CNC

Outdoor Optical Fiber CableDuct Cable Dry

Applications
- FTTx networks
- Indoor / Outdoor
- Suitable for underground duct installations

Features
- Single jacket with ripcords for easy stripping
- Contains non-metallic strength member
- PE Jacket


Mechanical Specifications
Fiber Count12 - 487296144288
432
432
567
864
Fibers per Tube12
24
Nominal Outer Diameter

10.2 mm

(0.40 in)

11.0 mm

(0.43 in)

12.3 mm

(0.48 in)

15.6 mm

(0.61 in)

18.6 mm

(0.73 in)

21.3 mm

(0.84 in)

18.5 mm

(0.73 in)

21.3 mm

(0.84 in)

24.4 mm

(0.96 in)

Max. Tensile Strength, Long-Term

620 N

(139 lb)

860 N

(193 lb)

Max. Tensile Strength, Short-Term

1800 N

(405 lb)

2500 N

(562 lb)

Min. Bend Radius Installation20 times x cable O.D.
Min. Bend Radius Operation

10 times x cable O.D.


Cable Design
Fiber Count12 - 487296144288432
567
864
Fiber Color  Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Pink, Aqua
Tube Color Coding  Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Pink, Aqua
Outer Jacket Color  Black
Outer Jacket Material  Polyethylene(PE)

Fiber Coloring( l : Black Stripe Marking)

General Specification
  Environment  Indoor / Outdoor
  Cable Type  Gel-free Tube
  Fiber Type  Single-Mode(OS2)
  Application  Duct

Standards
  RoHSFree of hazardous substances according to RoHS 2011/65/EU
  StandardsIEC60794 : Basic requirements for optical fiber and cable elements
ANSI/ICEA S-87-640 : Standard for optical fiber outside plant communications cable
  Design and Test CriteriaANSI/ICEA S-87-640

Ordering Information
Fiber Count12 - 487296144288432 (12F)
432 (24F)
567
864
Weight

70 kg/km

(47 lb/1,000ft)

84 kg/km

(56 lb/1,000ft)

103 kg/km

(69 lb/1,000ft)

165 kg/km

(111 lb/1,000ft)

217 kg/km

(146 lb/1,000ft)

271 kg/km

(182 lb/1,000ft)

216 kg/km

(145 lb/1,000ft)

261 kg/km

(175 lb/1,000ft)

324 kg/km

(218 lb/1,000ft)

Container Loading
Capacity
(40ft Container)
98 km
(320,000 ft)
98 km
(320,000 ft)
85 km
(280,000 ft)
79 km
(260,000 ft)
67 km
(220,000 ft)
55 km
(180,000 ft)
55 km
(180,000 ft)
55 km
(180,000 ft)
Requires discussion
Length / Reel6.096 km (20,000 ft)

Environmental Conditions
Temperature Range, Installation- 30 °C to +70 °C (-22 F to 158 F)
Temperature Range, Storage- 40 °C to +70 °C (-40 F to 158 F)
Temperature Range, Operation- 40 °C to +70 °C (-40 F to 158 F)

Optical Characteristics (Single-mode)
Fiber CategoryG.652.D
Attenuation after cable0.36 dB/km / 0.36 dB/km / 0.25 dB/km
Wavelengths1310 nm / 1383 nm / 1550 nm