HYESUNG CNC

Outdoor Optical Fiber CablePSAC Dry

Peelable Steel Armored Cable(PSAC) is composed of single-jacket, single-armored cables. It is designed for campus backbones in direct-buried installations.

The loose tube design provides stable and highly reliable transmission parameters for a variety of voice, data, video and imaging applications. These cables also provide high-fiber density within a given cable diameter while allowing flexibility to suit many system configurations.

The single armored construction provides additional crush and rodent protection with a high strength ripcord under the armor for easy stripping. Dry means the cables are fully water blocked using installation-friendly, water-swellable materials. This makes cable access simple, and requires no clean up. The flexible, installation- friendly buffer tubes are easy to route in closures, and the SZ-stranded, loose tube design isolates fibers from installation and environmental rigors while allowing easy mid-span access. These cables have a medium density polyethylene jacket that is rugged, durable, and easy to strip.

Features

  Trademark
  Dry water blocking technology
Installation-friendly cable preparation
  Polyethylene jacket

Rugged, durable and easy to strip (while providing superior protection against UV radiation, fungus, abrasion and other environmental factors)

  Corrugated steel tape armor
Provides rodent resistance for direct-buried applications

Specifications





Mechanical Specifications

 Fiber Count

12-48

72

96

144

288

432

432

576

864

 Fibers per Tube

12

12

12

12

12

12

24

24

24

 Nominal Outer Diameter[mm(in)]

11.4 mm    (0.45 in)
 12.2 mm    (0.48 in)
 13.5 mm    (0.53 in)
16.8 mm    (0.66 in)
19.8 mm    (0.77 in)
22.6 mm   (0.88 in)
  19.8 mm      (0.77 in)
22.5 mm   (0.88 in)
25.7 mm   (1.01 in)

 Max. Tensile Strength, Long-Term

800 N
(180 lb)
800 N

(180 lb)
800 N

(180 lb)
800 N

(180 lb)
800 N

(180 lb)
800 N

(180 lb)

 800 N

(180 lb)

 800 N

(180 lb)
800 N

(180 lb)

 Max. Tensile Strength, Short-Term

2700 N

(607 lb)

2700 N

(607 lb)

2700 N

(607 lb)

2700 N

(607 lb)

2700 N

(607 lb)

2700 N

 (607 lb)

 2700 N

(607 lb)

2700 N

 (607 lb)

2700 N

 (607 lb)

 Min.Bend Radius Installation

171 mm
(6.7 in)

183 mm
(7.2 in)

203 mm

(7.9 in)

252 mm

(9.9 in)

297 mm

(11.6 in)

339 mm

(13.3 in)

297 mm

(11.6 in)

338 mm

(13.3 in)

386 mm

(15.1 in)

 Min.Bend Radius Operation

114 mm
(4.5 in)

122 mm

(4.8 in)

   135 mm

(5.3 in)

   168 mm
    (6.6 in)

  198 mm
   (7.8 in)

226 mm
  (8.9 in)

  198 mm
    (7.8 in)

225 mm
  (8.9 in)

257 mm
   (10.1 in)

 Min. Bend Radius Installation

 20 times x cable O.D.

 Min. Bend Radius Operation

 10 times x cable O.D


Fiber Coloring( l : Black Stripe Marking)

General Specification
  Environment  Outdoor
  Cable Type  Dry Buffered Tube
  Product Type  Corrugated Steel Tape Armored
  Fiber Type  Single-Mode(OS2)
  Application  Duct, Direct-Buried

Standards
  RoHSFree of hazardous substances according to RoHS 2011/65/EU
  StandardsIEC60794 : Basic requirements for optical fiber and cable elements
ANSI/ICEA S-87-640 : Standard for optical fiber outside plant communications cable
  Design and Test CriteriaANSI/ICEA S-87-640


Ordering Information

 Fiber Count

12

12

12

12

12

12

24

24

24

 Fiber Count

12-48

72

96

144

288

432

432

576

864

Weight

116
kg/km 
(78 Ib/
1,000ft)
132
kg/km 
(89 Ib/
1,000ft)
157
kg/km 
(105 Ib/
1,000ft)
234
kg/km 
(157 Ib/
1,000ft)
297
kg/km 
(200 Ib/
1,000ft)
367
kg/km 
(246 Ib/
1,000ft)
276
kg/km 
(185 Ib/
1,000ft)
358
kg/km 
(241 Ib/
1,000ft)
436
kg/km 
(293 Ib/
1,000ft)

Container Loading

Capacity
(40ft Container)

98 km
(320,000
ft)
85 km
(280,000
ft)
73 km
(240,000
ft)
67 km
(220,000
ft)
55 km
(180,000
ft)
43 km
(140,000
ft)
55 km
(180,000

ft) 

43 km

(140,000
ft)
34 km

(112,000
ft)

Length/Reel

 6.096km
 (20,000ft)

 4.877km
 (16,000ft)

Environmental Conditions
Temperature Range, Installation- 30 °C to +70 °C (-22 F to 158 F)
Temperature Range, Storage- 40 °C to +70 °C (-40 F to 158 F)
Temperature Range, Operation- 40 °C to +70 °C (-40 F to 158 F)

Optical Characteristics (Single-mode)
Fiber CategoryG.652.D
Attenuation after cable0.40 dB/km / 0.40 dB/km / 0.25 dB/km
Wavelengths1310 nm / 1383 nm / 1550 nm