Applications
- FTTx networks
- Indoor / Outdoor
- Suitable for underground duct installations
Features
- Single jacket with ripcords for easy stripping
- Contains non-metallic strength member
- PE Jacket 			
| Mechanical Specifications | |||||||||
| Fiber Count | 12 - 48 | 72 | 96 | 144 | 288 | 432  | 432  | 576  | 864  | 
| Fibers per Tube | 12 | 24  | |||||||
| Nominal Outer Diameter | 9.1 mm (0.36 in)  | 9.7 mm (0.38 in)  | 11.0 mm (0.43 in)  | 13.6 mm (0.54 in)  | 15.9 mm (0.63 in)  | 18.1 mm (0.71 in)  | 16.9 mm (0.67 in)  | 19.8 mm (0.78 in)  | 22.3 mm (0.88 in)  | 
| Max. Tensile Strength, Long-Term | 450 N (101 lb)  | 640 N (144 lb)  | |||||||
| Max. Tensile Strength, Short-Term | 1200 N (270 lb)  | 2200 N (495 lb)  | |||||||
| Min. Bend Radius Installation | 20 times x cable O.D. | ||||||||
| Min. Bend Radius Operation | 10 times x cable O.D.  | ||||||||
| Cable Design | ||||||||
| Fiber Count | 12 - 48 | 72 | 96 | 144 | 288 | 432 | 576  | 864  | 
| Fiber Color | Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Pink, Aqua | |||||||
| Tube Color Coding | Blue, Orange, Green, Brown, Slate, White, Red, Black, Yellow, Violet, Pink, Aqua | |||||||
| Outer Jacket Color | Black | |||||||
| Outer Jacket Material | Polyethylene(PE) | |||||||
| Fiber Coloring( l : Black Stripe Marking) | 
![]()  | 
| General Specification | |
| Environment | Indoor / Outdoor | 
| Cable Type | Gel-filled Tube | 
| Fiber Type | Single-Mode(OS2) | 
| Application | Duct | 
| Standards | |
| RoHS | Free of hazardous substances according to RoHS 2011/65/EU | 
| Standards | IEC60794 : Basic requirements for optical fiber and cable elements ANSI/ICEA S-87-640 : Standard for optical fiber outside plant communications cable  | 
| Design and Test Criteria | ANSI/ICEA S-87-640 | 
| Ordering Information | |||||||||
| Fiber Count | 12 - 48 | 72 | 96 | 144 | 288 | 432 (12F) | 432 (24F)  | 576  | 864  | 
| Weight | 61 kg/km (41 lb/1,000ft)  | 73 kg/km (49 lb/1,000ft)  | 93 kg/km (62 lb/1,000ft)  | 146 kg/km (98 lb/1,000ft)  | 197 kg/km (132 lb/1,000ft)  | 249 kg/km (167 lb/1,000ft)  | 215 kg/km (144 lb/1,000ft)  | 290 kg/km (195 lb/1,000ft)  | 374 kg/km (251 lb/1,000ft)  | 
| Container Loading Capacity (40ft Container)  | 98 km (320,000 ft)  | 98 km (320,000 ft)  | 85 km (280,000 ft)  | 79 km (260,000 ft)  | 67 km (220,000 ft)  | 55 km (180,000 ft)  | 67 km (220,000 ft)  | 55 km (180,000 ft)  | Requires discussion  | 
| Length / Reel | 6.096 km (20,000 ft) | ||||||||
| Environmental Conditions | |
| Temperature Range, Installation | - 30 °C to +70 °C (-22 F to 158 F) | 
| Temperature Range, Storage | - 40 °C to +70 °C (-40 F to 158 F) | 
| Temperature Range, Operation | - 40 °C to +70 °C (-40 F to 158 F) | 
| Optical Characteristics (Single-mode) | |
| Fiber Category | G.652.D | 
| Attenuation after cable | 0.36 dB/km / 0.36 dB/km / 0.25 dB/km | 
| Wavelengths | 1310 nm / 1383 nm / 1550 nm | 
Datasheet download  | Duct (Gel) Cable Datasheet |